Digital Storage Oscilloscope

100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main


100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main

100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main    100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main
Digital storage oscilloscope, built-in 1CH 25MHz signal generator, which makes electronic maintenance and car maintenance more convenient. Abundant SCPI remote control commands. Trigger: edge, pulse, video, slope, timeout, window, pattern, interval, runt, UART, LIN, CAN, SPI, IIC. It can save settings, waveforms, reference waveforms, CSV, pictures and other data formats.

Support threshold test, realize measurement in the screen. Item Type: Digital Storage Oscilloscope Material: ABS Weight: Approx. Number of average waveforms: 4, 8, 16, 32, 64, 128. DC, AC or ground (DC, AC, GND). 2ns/div-100s/div, 1, 2, 5 steps.

Edge trigger, pulse width trigger Video trigger, slope trigger, timeout trigger Window trigger, pattern trigger, interval trigger, runt trigger, UART trigger, LIN trigger, CAN trigger, IIC trigger. V Time difference between cursors? Double value, frequency, average value, maximum value, minimum value, period, top value, middle value, bottom value, amplitude, root mean square, rising edge overshoot, falling edge preshoot, period root mean square, period Average value, rise time, fall time, positive pulse width, negative pulse width, positive duty cycle, negative duty cycle, FRR, for FFF, falling edge overshoot, rising edge preshoot, pulse width, FRF, FFR, LRR, LRF, LFR, LFF. =+, -, ×, ÷, FFT.

Rectangular, for Hanning, for Heming, for Blackman, for Bartlett, flat roof. Sine , square , ramp , Exp, noise, DC.

800 (horizontal) x 480 (vertical) pixels. 1s, 5s, 10s, 30s, infinite. How to Use: 2: Set the switch on the probe to X10 and connect the probe to channel 1 of the oscilloscope.

4: Observe whether it is a square, adjust the probe to keep the probe in the best state (the waveform is normal). 5: Measurement Operating Instructions of the Signal Generator 1. Connect EXT TRIG GEN OUT and connect the other end to the unit that needs to receive signals 2. Press GEN to start the signal generator. Press F1 to select waveform, sine, square, DC, etc. Press GEN, F2 frequency, period selection, F3 amplitude selection 4. 1 x USB Data Cable. We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. Post a message again because sometimes our message system may block some emails.

If you are satisfied with our service, pls. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better. We strive to keep all our customers satisfy. We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders.


100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main    100MHz Digital Storage Oscilloscope Efficient 2CH 1GSa/s For Electronic Main