400V (DC+AC peak value, 1M input impedance). Single channel 2GSa/s; dual channel 1GSa/s. Single channel 1GSa/s, dual channel 500MSa/s (only to GA1102CAL). Sampling, peak value detection, average value. 4, 16, 32, 64, 128, 256.
2mV/div - 5V/div (1-2-5 step-by-step). ±10div offset from the screen center. 25MHz(only to GA1022CAL) 300MHz(only to GA1302CAL).
100MHz(only to GA1102CAL) 200MHz(only to GA1202CAL). 60MHz(only to GA1062CAL) 40MHz(only to GA1042CAL). 2mV/div ±4%, the rest gears ±3%. ±[DC measurement accuracy x reading+ (1% x vertical displacement reading) +0.2div]. +, -, × , ÷ , FFT. Window mode: Hanning, Hamming, Blackman.2ns/div 50s/div, step 32 gears according to sequence. 1ns/div 50s/div, step 33 gears according to sequence. Wherein, 100ms/div 50s/div is the scan shift. Edge, pulse, video, slope, alternation. CH1, CH2, EXT, EXT/5, AC Line.
DC, AC, Low-frequency rejection, high-frequency rejection. Type: rise, descend, rise and descend edge. Pulse width resolution: 5ns or 1 (take the higher value). Support signal system: PAL, NTSC.
Trigger condition: odd field, even field, all rows, specified row. CH1 trigger type: edge, pulse, video, slope. CH2 trigger type: edge, pulse, video, slope. Maximal valve, minimal value, peak-to-peak value, amplitude, top value, bottom value, periodic average value, average value, periodic mean square root, mean square root, rise extreme, descend extreme, rise time, descend time, frequency, period, pulse width, positive pulse width, negative pulse width, positive duty ratio, negative duty ratio, phase, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF.
Manual measurement mode, cursor tracking measurement mode. The auto setup function can realize automatic regulation of the vertical system, the horizontal system and the trigger position. 2 groups of reference waveform, 16 groups of common waveform, 16 groups of setups; save and recall from USB flash drive of the waveform, setups, CSV and bitmap files (CSV and the bitmaps cannot be recalled from the USB flash disc) are supported.
Alternating-current coupling, from 10Hz to the maximal bandwidth. All sources capable of being triggered in pulse trigger or edge trigger type.800 (horizontal) pixels x 480 (vertical) pixels. Off, 1 second, 2 seconds, 5 seconds, infinite. 2 seconds, 5 seconds, 10 seconds, 20 seconds, infinite. Off, 1min, 2min, 5min, 10min, 15min, 20min, 1h, 2h, 5h.
100-240 VAC, CAT II, auto selection. AC power supply frequency range. Operating: 10 ºC to +40 ºC.Non operating: -20 ºC to +60 ºC. Non operating: smaller than 15000m.
339mm×149mm×111mm (width x height x depth). We will handle your message within 24 hours.
Sorry for delay reply on weekend. Out of duty on Saturday afternoon and Sunday! Thanks for your shopping with us and wish you enjoy it.Hope we have a long relationship and see you again. For negative or neutral feedback won't solve any problems for you. We promise that we will try our best to solve your problems and give you the most satisfaction.
If you have any unsatisfaction, please let me know firstly and give me an opportunity to solve problem for you. Most important: we are aim to you give you the best service and most satisfaction, hope you could rate.
And this will be stimulated us to give you the better and better service. The item "ATTEN ADS GA1062CAL Digital Storage Oscilloscope 60MHz 1G 2 Channel" is in sale since Friday, July 28, 2017. This item is in the category "Business & Industrial\Test, Measurement & Inspection\Analyzers & Data Acquisition\Oscilloscopes & Vectorscopes". The seller is "autoobd2" and is located in shenzhen, .
This item can be shipped worldwide.