It has the functions of digital voltmeter and hardware frequency meter, two groups of digital voltmeter functions. Built-in a 25MHz signal generator, rich SCPI remote control commands, support threshold testing, and realize measurement on the screen. Support 32 kinds of automatic measurement and statistics functions, real-time statistics of minimum, maximum, standard deviation and other information. It is a rare debugging instrument in many industries and fields such as communications, aerospace, defense, embedded systems, computers, research and education. The shell is made of high-quality ABS material, wear-resistant and durable, not easy to damage, and long service life.
Item Type: Digital Storage Oscilloscope Material: ABS. Display High Frequency and Random Glitches.
Average Waveform Times: 4, 8, 16, 32, 64, 128. DC, AC or ground (DC, AC, GND). Maximum 8M for Single Channel.Maximum 4M for Dual Channels. 2ns/div-100s/div, 1, 2, 5 Steps. ±0.5divX Minimum Time Base Gear. Edge, Pulse, Video, Slope, Timeout, Window, Pattern, Interval, Runt, UART, LIN, CAN, SPI, IIC Trigger. Double Value, Frequency, Average Value, Maximum Value, Minimum Value, Period, Top Value, Middle Value, Bottom Value, Amplitude, Root Mean Square, Rising Edge Overshoot, Falling Edge Preshoot, Period Root Mean Square, Period Average, Rise Time, Fall Time, Positive Pulse Width, Negative Pulse Width, Positive Duty Cycle, Negative Duty Cycle, FRR, FFF, Falling Edge Overshoot, Rising Edge Preshoot, Pulse Width, FRF, FFR, LRR, LRF, LFR, LFF.
DC RMS, AC RMS, DC. =+, -, ×, ÷, FFT. Rectangular, Hanning, Heming, Blackman, Bartlett, Flat Top.Single Display or Full Display. 9 types of files can be saved and recalled internally, including settings, waveforms, and references.
CSV file, BMP picture (24 digits). Sine, square, ramp, Exp, noise, DC. Support PC download and external memory recall.
The diagonal is 7in TFT LCD screen. 800 (Horizontal)x480 (Vertical) pixels. 1s, 5s, 10s, 30s, Unlimited. How to Use: 1: Plug in the power and turn on 2: Set the switch on the probe to X10 and connect the probe to channel 1 of the oscilloscope. To do this, align the slot on the probe connector with the protrusion on the CH1 BNC, press it down to connect, then turn to the right to lock the probe in place, and connect the probe tip and reference to the probe elements connection On the device, the label on the panel is: 5V at lKHz.3: Press the Auto Set button. The screen shows a square with a frequency of 1kHz and a voltage of 5V -to.
4: Observe whether it is a square, adjust the probe to keep the probe in the best state (the waveform is normal). 5: Measurement Operating Instructions of the Signal Generator: 1: Connect EXT TRIG GEN OUT and connect the other end to the unit that needs to receive signals 2: Press GEN to start the signal generator. Press F1 to select waveform, sine, square, DC, etc. (standard) 3: Press GEN, F2 frequency, period selection, F3 amplitude selection 4: Confirm the waveform emission. 1 x USB Data Cable. We will reply your message within 48 hours. If you do not receive our reply within 48 hours, pls. Post a message again because sometimes our message system may block some emails. If you are satisfied with our service, pls. Our aim is to provide Level Customer Service, your recognition will encourage us greatly and serve you better. We strive to keep all our customers satisfy. We will do our up most to exceed your expectations in customer service, communication and dispatching of your orders.