Selectable 18650 battery box for matching 18650 battery by yourself. Anti-theft lock hole, tripod fixed hole, hang rope, FLASH light that can be used in darkness. Replaceable BNC safety joints, and additional one set of joints. High bandwidth 70MHz-200MHz Oscilloscope, 1GSa/s sample rate, 2M Memory depth. Waveform Generator, 200 Mesa/s DDS, 12 bit vertical resolution, easy for simulating transducer.
6000 Counts DMM, AC/DC voltage, AC/DC current, resistance, break, capacitance, and diode function. FFT spectral analysis; Waveform Math: add, subtract, multiply and divide; X-Y mode; more than 20 automatic measurements; PASS/FAIL Check function, apply to engineering application.
Abundant trigger function, double timebase sampling, easy to observe two waveforms in different frequency. Record and replay of more than 1000 waveforms. Large 5.6 inch TFT Color LCD Display; High Resolution(640480). USB Host/Device 2.0 full-speed interface; support removable disk; WIFI/LAN Option, easy to control by PC or long-distance. Waveform data can be output in WORD, EXCEL, BMP, JPG as time and voltage. High-frequency and randon glith capture. Wavefom Average, selectable 4,8,16,32,64,128. CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×). 4ns/div2000s/div, in a 2, 4, 8 sequence. 2ns/div2000s/div, in a 2, 4, 8 sequence. Sample Rate and Delay Time Accuracy. ±50ppm over any =1ms time interval. 4ns/div to 8ns/div; (-8div x s/div) to 40ms; 20ns/div to 80µs/div;(-8div×s/div) to 40ms; 200µs/div to 40s/div;(-8div×s/div) to 400s. 2ns/div to10ns/div;(-4div×s/div) to 20ms. Delta Time Measurement Accuracy (Full Bandwidth).Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200. 8-bit resolution, all channel sampled simultaneously. 2mV/div to 100V/div at input BNC.
Rise Time at BNC(typical). Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled. ±400V(100V/div-20V/div); ±50V(10V/div-5V/div); ±40V(2V/div-500mV/div); ±2V(200mV/div-50mV/div); ±400mV(20mV/div-2mV/div). Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point.
±3% for Normal or Average acquisition mode, 100V/div to 10mV/div. ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div.
DC Measurement Accuracy, Average Acquisition Mode. Measurement Type: Average of =16 waveforms with vertical position at zero Accuracy: ± (3% × reading + 0.1div + 1mV) when 10mV/div or greater is selected. Measurement Type: Average of =16 waveforms with vertical position not at zero Accuracy: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]. Volts Measurement Repeatability, Average Acquisition Mode.
Delta volts between any two averages of =16 waveforms acquired under same setup and ambient conditions. Edge, Video, Pulse, Slope, Over time, Alternative.
DC, AC, HF Reject, LF Reject, Noise Reject. Trigger Sensitivity (Edge Trigger Type). DC(CH1, CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; AC: Attenuates signals below 10Hz ; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz. CH1/CH2: ±8 divisions from center of screen.Trigger Level Accuracy(typical)Accuracy is for signals having rise and fall times =20ns. CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen.
Set Level to 50%(typical). Operates with input signals =50Hz. CH1, CH2: Peak-to-peak amplitude of 2 divisions. Signal Formats and Field Rates.Supports NTSC, PAL and SECAM broadcast systems for any field or any line. ; Positive pulse or Negative pulse. Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
; Positive slope or Negative slope. Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Rising edge or Falling edge. Internal Trigger: Edge, Pulse Width, Video, Slope. ±30ppm (including all frequency reference errors and ±1 count errors). AC coupled, from 4Hz minimum to rated bandwidth.
Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to.
Manual: Voltage difference between cursors:? V Time difference between cursors:? T in Hertz (1/dT); Tracing: The valtage and time at a waveform point. Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS. 640 horizontal by 480 vertical pixels.
Adjustable (16 gears) with the progress bar. AC Input:100-240VACRMS, 0.6A MAX, 50Hz60Hz; DC Output:9V, 2A. Or below: =90% relative humidity; 106?
Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet). Voltage, Current, Resistance, Capacitance, Diode & Continuity. Attention: the smallest capacitance value that can be measured in 5nF.1 x CD Manual etc. Due to the lighting effects and shooting angles, there is a color difference in the product, please understand. Due to manual measurement, there is a tolerance in the product size. We offer a 30 days return guarantee.
If you are not satisfied with the item, you can return it within 30 days after item received. We will try our best to resolve the issues. Please give us the opportunity to resolve any problem. This item is in the category "Business & Industrial\Test, Measurement & Inspection\Analyzers & Data Acquisition\Oscilloscopes & Vectorscopes". The seller is "tiqi60" and is located in this country: CN.This item can be shipped worldwide.