1 2 channels, both are respectively controlled by independent knobes. 1 GSa/s real-time sample rate.
8 CAN decode and protocol analysis. 9 Can save as multiple data formats, such as setting, waveform, referance waveform, CSV, picture.
5 bits digital voltage meter and 6 bits hardware frequency indicator function. 11 32 kinds of auto measurements with statistics, real-time statistics of maxmum, minimum, standrad deviation and etc.
12 2 sets of digital voltmeter. 13 Support threshold testing, free measurements within the screen.
DSO2C10 have no waveform generator function! 1GSa/s (single channel) 500MSa/s (two channels). Display high frequency and random burr. Average waveform, times: 4, 8, 16, 32, 64, 128.
2ns/div100s/div 1, 2, 5 step by step. ±0.5 div×minimum time base gear. Sample Rate and Delay Time Accuracy.
Delta Time Measurement Accuracy (Full Bandwidth)Sample Rate and Delay Time Accuracy. ±50ppm(at any interval greater than 1ms).Rising time in BNC position (typical). 8 bits resolution, each channel samples simultaneously. +, -, ×, ÷, FFT. Window: Rectangle, Hanning, Hamming, Blackman, Bartlett, Flattop.
In BNC position = 10Hz. In''normal'' or''average'' acquisition mode, the accuracy of 10V/div to 10mV/div is ±3%. In''normal'' or''average'' acquisition mode, the accuracy of 5mV/div to 2mV/div is ±4%. Note: Bandwidth reduced to 6MHz when using a 1X probe. Edge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC.±5 divisions from the center of the screen. ±4 divisions from the center of the screen. 0.2 div×volts/div within ±4 divisions from the center of the screen. Rising edge, falling edge, rising or falling edge.
Scanning line, line number, odd field, even field, all field. 0: low level; 1: high level; X: ignore.Start, Stop, data, Parity ERR, COM ERR. 5 bit, 6 bit, 7 bit, 8 bit. Interval field, synchronization field, ID field, synchronization error, identifier, ID and data. Start bit, remote frame ID, data frame ID, frame ID, data frame data, error frame, all errors, ACK Error, overload frame.
10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000. 4, 8, 16, 24, 32.
Start bit, stop bit, No Ack, address, restart, address and data. Frequency, period, mean, peak-to-peak, RMS, minimum, mixmum, rising time, falling time, + width, - width, base, top, middle, amplitude, overshoot, preshoot, rising edge phase difference, falling edge phase difference, + duty, - duty, period mean, PRMS, FOVshoot, ROVshoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF. Hardware 6 bits frequency meter.
Sine, square, ramp, Exp, noise, DC. 0.1 Hz to 10 MHz. 0.1 Hz or 4 bits, take the greater one. ±3.5 V, high impedance. ±1.75 V, 50 O. 100 µV or 3 bits, take the greater one. 800 (horizontal)480 (vertical) pixels. 16 million colours (24 bits true colour).Minimum, 1 s, 5 s, 10 s, 30 s, infinite. About 2Vpp input =1MO load. (±10%), 45Hz to 66Hz, CAT? T, 3.15A, 250V, 5x20mm. 40+71 °C (-40159.8 °F).
(+41°C 50°C): =60% relative humidity. 3, 000m (10, 000 feet). 10 minutes on each axis. 318 x 110 x 150mm (length x width x height).If the package you received has any damage or defect, you need to send us a picture of the condition of your item, we will try our best to solve the problem for you according to the specific situation. The arrival time depends on some factors and different areas. If there is any delay, it may be caused by bad weather or custom inspection which is not in our control, but don't worry, we will keep to follow your order until you receive it. OUR WORKING Time(Beijing):9:00am6:00pm(MondayFriday).
We apologize for the late reply during the holidays. Hantek 1008C 8CH PC USB Automotive Diagnostic Digital Oscilloscope/DAQ/Programma.Hantek DSO2D10 2CH Digital Storage Oscilloscope 100MHz 1GSa/s 8M w/Signal Source. Hantek 6022BE 2-CH PC-Based USB 48MSa/s 20MHz Digital Storag Oscilloscope.
Hantek HT25COP ignition waveform of automobile engine Coil on Plug Signal Probe. Hantek PP-200 PP-250 PP-300 200MHz 250MHZ 300MHZ Oscilloscope Clip Port Probe. Hantek 6022BL Based USB PC 48MSa/s Digital Oscilloscope Logic Analyzer 16 CH.
Hantek HT18A fitting of DSO3064 2PCS Large Dolphin Gator Clips Red+Black. Hantek DSO2D15 2CH 150MHz Digital Storage Oscilloscope 1GSa/S with 1CH AWG.
Hantek 2D72 2C72 2D42 2C42 Handheld Oscilloscope Digital 3in1 Multimeter Tester. Hantek DSO2C15 Digital Storage Oscilloscope 2CH 150Mhz Bandwidth 1GS/s Samle Rat. Hantek HT20COP Coil on Plug Signal Probe Ignition Waveform of Automobile Engine.
HANTEK 6104BE 6204BE 6254BE 100Mhz 200MHz 250MHz USB PC Automotive Diagnostic. Hantek 1008A 8 CH Portable USB2.0 Auto Diagnostic Digital Oscilloscope. Hantek DSO5072P DSO5102P DSO5202P 70MHZ 100MHZ 200MHz Oscilloscope 2CH 1GSa/s.This item is in the category "Business & Industrial\Test, Measurement & Inspection\Analyzers & Data Acquisition\Oscilloscopes & Vectorscopes". The seller is "igucee" and is located in this country: CN. This item can be shipped worldwide.