1GSa/s Real Time sample rate. Large (7.0-inch) color display, WVGA(800x480). Record length up to 40K.
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc. USB host and device connectivity, standard. Four math functions, including FFTs standard. Provides software for PC real-time analysis. Real-Time Sample: 1GS/s Equivalent Sample: 25GS/s.
Wavefom Average, selectable 4,8,16,32,64,128. 20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s. Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200. 2mV/div to 200mV/div, ±2V 200mV/div to 5V/div, ±50V. 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50V.Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point. ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div. When vertical displacement is zero, and N =16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N=16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div. Edge, Video, Pulse, Slope, Over time, Alternative. CH1, CH2, EXT, EXT/5, AC Line.
DC, AC, Noise Reject, HF Reject, LF Reject. CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V.CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V. Internal Trigger: Edge, Pulse Width, Video, Slope.
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF. 100-120VACRMS(±10%), 45Hz to 440Hz, CATII 120-240VACRMS(±10%), 45Hz to 66Hz, CATII. Operating: 32F to 122F (0C to 50C); Nonoperating: -40F to 159.8F (-40C to +71C). +104F or below (+40C or below): =90% relative humidity; 106F to 122F (+41C to 50C): =60% relative humidity.Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet). 3.5KG(with Packing); 2.08KG(without Packing).
This item is in the category "Business & Industrial\Test, Measurement & Inspection\Analyzers & Data Acquisition\Oscilloscopes & Vectorscopes". The seller is "jiamianvery" and is located in this country: CN. This item can be shipped worldwide.