Hantek DSO2C10/2D10 Digital Storage Oscilloscope 2CH 100Mhz 1GS/s Signal Source. 1 2 channels, both are respectively controlled by independent knobes. 1 GSa/s real-time sample rate.
Built-in 1 CH 25MHz waveform generator. 9 CAN decode and protocol analysis. 10 Can save as multiple data formats, such as setting, waveform, referance waveform, CSV, picture. 5 bits digital voltage meter and 6 bits hardware frequency indicator function.12 32 kinds of auto measurements with statistics, real-time statistics of maxmum, minimum, standrad deviation and etc. 13 2 sets of digital voltmeter. 14 Support threshold testing, free measurements within the screen.
DSO2C10 have no waveform generator function! 1GSa/s (single channel) 500MSa/s (two channels). Display high frequency and random burr. Average waveform, times: 4, 8, 16, 32, 64, 128. 2ns/div100s/div 1, 2, 5 step by step.
±0.5 div×minimum time base gear. Sample Rate and Delay Time Accuracy. Delta Time Measurement Accuracy (Full Bandwidth)Sample Rate and Delay Time Accuracy. ±50ppm(at any interval greater than 1ms). Rising time in BNC position (typical).
8 bits resolution, each channel samples simultaneously. +, -, ×, ÷, FFT.
Window: Rectangle, Hanning, Hamming, Blackman, Bartlett, Flattop. In BNC position = 10Hz. In''normal'' or''average'' acquisition mode, the accuracy of 10V/div to 10mV/div is ±3%. In''normal'' or''average'' acquisition mode, the accuracy of 5mV/div to 2mV/div is ±4%. Note: Bandwidth reduced to 6MHz when using a 1X probe. Edge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC. ±5 divisions from the center of the screen.±4 divisions from the center of the screen. 0.2 div×volts/div within ±4 divisions from the center of the screen.
Rising edge, falling edge, rising or falling edge. Scanning line, line number, odd field, even field, all field. 0: low level; 1: high level; X: ignore. Start, Stop, data, Parity ERR, COM ERR. 5 bit, 6 bit, 7 bit, 8 bit.Interval field, synchronization field, ID field, synchronization error, identifier, ID and data. Start bit, remote frame ID, data frame ID, frame ID, data frame data, error frame, all errors, ACK Error, overload frame. 10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000.
4, 8, 16, 24, 32. Start bit, stop bit, No Ack, address, restart, address and data. Frequency, period, mean, peak-to-peak, RMS, minimum, mixmum, rising time, falling time, + width, - width, base, top, middle, amplitude, overshoot, preshoot, rising edge phase difference, falling edge phase difference, + duty, - duty, period mean, PRMS, FOVshoot, ROVshoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF.
Hardware 6 bits frequency meter. Sine, square, ramp, Exp, noise, DC. 0.1 Hz to 10 MHz. 0.1 Hz or 4 bits, take the greater one.
±3.5 V, high impedance. ±1.75 V, 50 O.
100 µV or 3 bits, take the greater one. 800 (horizontal)480 (vertical) pixels. 16 million colours (24 bits true colour).
Minimum, 1 s, 5 s, 10 s, 30 s, infinite. About 2Vpp input =1MO load. (±10%), 45Hz to 66Hz, CAT? T, 3.15A, 250V, 5x20mm.
40+71 °C (-40159.8 °F). (+41°C 50°C): =60% relative humidity.3, 000m (10, 000 feet). 10 minutes on each axis.
318 x 110 x 150mm (length x width x height). Thank you for your support. We stand behind every product we sell.
However, we will try our best to minimize it. You can enjoy top-quality product and high-quality services from us, Trust me that you will have a pleasant shopping experience in here. This item is in the category "Business & Industrial\Test, Measurement & Inspection\Analyzers & Data Acquisition\Oscilloscopes & Vectorscopes".
The seller is "ashleytrade1984*" and is located in this country: CN. This item can be shipped worldwide.