80-250MHz bandwidthminimum range 500V /div1GS/s sample rate. Over 32 types of auto measurement function.
Advanced digital trigger system, high trigger sensitivity. Over 14 types of trigger function: edge, overtime, pulse, pattern, interval, etc.
Function/arbitrary signal generator25MHz, 12BitS resolution, 200MHz DDS, ARB/square wave/sine wave/triangular wave/trapezoidal wave/impulse wave/DC etc. Easy to simulate the sensor. Integrated USB Host/Device, convenient to communicate with PC. Support a variety of SCPI remote control command.
Support optional RS232 port, LAN port, HDMI port, touch screen, WIFI communication, SD card storage. Stable and reliable quality, sturdy and durable. Maximum 64K samples per single-channel.Maximum 32K samples per dual-channel (4K, 32K optional). ± (1 sample interval +100ppm × reading + 0.6ns). ± (1 sample interval + 100ppm × reading + 0.4ns).
Sample interval = s/div ÷ 200. 8-bit resolution, each channel sampled simultaneously. 500V/div to 10V/div at input BNC. Selectable Analog Bandwidth Limit, typical. Rise Time at BNC, typical. ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div. ±4% for Normal or Average acquisition mode, 5mV/div to 500V/div.Note: Bandwidth reduced to 6MHz when using a 1X probe. Normal, Peak Detect, Average and HR. Up to 2000 waveforms per second per channel (Normal acquisition mode, no measurement).
Upon single acquisition on all channels simultaneously. After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128. ±4 divisions from center of screen. 0.2div × volts/div within ±4 divisions from center of screen. ± (6% of setting + 40mV). ScanLine, LinrNum, OddField, EvenField and AllField. 0: Lower level; 1: High level. Start, Stop, Data, Parity Error, COM Error. 5 bit, 6 bit, 7 bit, 8 bit. Interval Field, Sync Field, Id field, Sync Id Error, Identifier, Id and Data. Start Bit, Remote Frame, Data Frame Id, Frame Id, DataFrame Id A, Error Frame, All Error, Ack Error, Overload Fram. 10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000. 4, 8, 16, 24, 32.Start, Stop, No Ack, Address, Data, Restart. Voltage difference between cursors: V. Time difference between cursors: T.
Reciprocal of T in Hertz (1/T). Frequency, Period, Average, Pk-Pk, RMS, PeriodRms, Min, Max, RiseTime, FallTime, + Width, - Width, + Duty, - Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, PeriodAvg, FOVShoot, RPREShoot, BWidth, FRR, FFF, FRF, FFR, LRR, LRF, LFR and LFF. 7 inch 64K color TFT (diagonal liquid crystal). 800 horizontal by 480 vertical pixels.
About 2Vpp into 1M load. 100-120VACRMS(±10%), 45Hz to 440HzCAT 120-240VACRMS(±10%), 45Hz to 66HzCAT. 40+71 °C (-40159.8 °F). +104(+40°C): 90% relative humidity. 106122 (+41°C 50°C): 60% relative humidity. 10 minutes on each axis.318 x 110 x 150mm(L x W x H). 5mV3.5Vp-p(50) 10mV7Vp-p(High impedance).
The standard package don't include batteries. If you have any questions or comments whatsoever regarding our products or listing, we are waiting to hear from you. If the product malfunctioned under proper usage per instructions. 30 days evaluation and investigation takes placed after receiving your return item.
The item "Hantek DSO4204C Digital Storage Oscilloscope 64K 4CH 200MHz+signal source 1GS/s" is in sale since Tuesday, November 26, 2019. This item is in the category "Business & Industrial\Test, Measurement & Inspection\Analyzers & Data Acquisition\Oscilloscopes & Vectorscopes".
The seller is "instrument_queen" and is located in ShenZhen. This item can be shipped worldwide.