Hantek DSO4254C Digital Oscilloscope 4 Channels 250Mhz PC Portable USB Oscilloscopes +. 4CH oscilloscope, with 1CH Arbitary/function waveform generator, independent keys of oscilloscope and waveform generator which is easy to operate at the same time.. 80-250MHz bandwidth, minimum measurement range 500? V /div, 1GS/s sample rate, advanced digital trigger system, high trigger sensitivity, low trigger jitter, high resolution 7 inch 64K color TFT (800480). 80-250MHz bandwidth, minimum range 500? V /div, 1GS/s sample rate. Over 32 types of auto measurement function. Advanced digital trigger system, high trigger sensitivity. Over 14 types of trigger function: edge, overtime, pulse, pattern, interval, etc. Function/arbitrary signal generator25MHz, 12BitS resolution, 200MHz DDS, ARB/square wave/sine wave/triangular wave/trapezoidal wave/impulse wave/DC etc. Easy to simulate the sensor.

Integrated USB Host/Device, convenient to communicate with PC. Support a variety of SCPI remote control command. Support optional RS232 port, LAN portStable and reliable quality, sturdy and durable. Maximum 64K samples per single-channel.

Maximum 32K samples per dual-channel (4K, 32K optional). ± (1 sample interval +100ppm × reading + 0.6ns). ± (1 sample interval + 100ppm × reading + 0.4ns). Sample interval = s/div ÷ 200.

V/div to 10V/div at input BNC. Selectable Analog Bandwidth Limit, typical.

Rise Time at BNC, typical. ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div. ±4% for Normal or Average acquisition mode, 5mV/div to 500? Note: Bandwidth reduced to 6MHz when using a 1X be. Normal, Peak Detect, Average and HR. Up to 2000 waveforms per second per channel (Normal acquisition mode, no measurement). Upon single acquisition on all channels simultaneously. After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128. ±4 divisions from center of screen. 0.2div × volts/div within ±4 divisions from center of screen. ± (6% of setting + 40mV).

ScanLine, LinrNum, OddField, EvenField and AllField. 0: Lower level; 1: High level. Start, Stop, Data, Parity Error, COM Error.

5 bit, 6 bit, 7 bit, 8 bit. Interval Field, Sync Field, Id field, Sync Id Error, Identifier, Id and Data. Start Bit, Remote Frame, Data Frame Id, Frame Id, DataFrame Id A, Error Frame, All Error, Ack Error, Overload Fram. 10000, 20000, 33300, 500000, 62500, 83300, 100000, 125000, 250000, 500000, 800000, 1000000. 4, 8, 16, 24, 32.

Start, Stop, No Ack, Address, Data, Restart. Frequency, Period, Average, Pk-Pk, RMS, PeriodRms, Min, Max, RiseTime, FallTime, + Width, - Width, + Duty, - Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, PeriodAvg, FOVShoot, RPREShoot, BWidth, FRR, FFF, FRF, FFR, LRR, LRF, LFR and LFF. 7 inch 64K color TFT (diagonal liquid crystal). 800 horizontal by 480 vertical pixels. 100-120VACRMS(±10%), 45Hz to 440Hz, CAT?

120-240VACRMS(±10%), 45Hz to 66Hz, CAT? 40+71 °C (-40159.8 °F). 3,000m(10,000 feet). 10 minutes on each axis.

318 x 110 x 150mm(L x W x H). If you have any questions or comments whatsoever regarding our ducts or listing, we are waiting to hear from you. If the duct malfunctioned under per usage per instructions. 30 days evaluation and investigation takes placed after receiving your return item. If you need us send the item to other address, please tell us.