English, Portuguese, Spanish, French, Dutch, German, Russian. 100MHz bandwidths; 500Ms/S Real Time sample rate; Dual analog channels wide vertical range 1mV/div20V/div. With copy function for fast storage infomation; Record length up to 32K, and waveform record up to 1000 screen.
High accuracy and wide measurement range meet different analyze demands. Supports plug-and-play USB storage device.
Communication with and remote control of computer through the USB device. Multilingual menu available, with multiple functional button for fast operation.
Large Display More Easy Reading. 7 inch large TFT LCD display with 800×480 pixels RGB, large and vivid more, make monitor and analyze work more easy.Electronic circuit debugging / circuit testing / design and manufacture / education and training / automobile maintenance and testing. 2 channels simultaneously, can counter the average of 2 n times.
And n=18 positive integers can be selected. ±2%, in parallel with 20pF±3pF. input resistance)(10:1 be attenuation). 2ns/div 50s/div, step by 1-2-5.
Sampling Rate / Relay Time Accuracy. Single:± (1 interval time + 50ppm × reading + 0.6ns).
16 : ±(1 interval time + 50ppm × reading + 0.4ns). 8 bits (2 channels simultaneously). Low frequency response (AC coupling, -3dB).
As Vertical sensitivity is 1mV5mV/div:±4%. (acquisition or average value acquisition modes). As Vertical sensitivity is 10mV/div20V/div:±3%. DC Measurement Accuracy(average value acquisition modes).Vertical displacement = 0, and N? ±(5%×reading + 0.1div + 1mV)and select 1mV/div or 2mV/div. ±(4%×reading + 0.1div + 1mV)and select 5mV/div. ±(3%×reading + 0.1div +1mV)and select 10mV/div20V/div.
±[3%×(reading + Vertical displacement reading)+(1%×Vertical displacement reading)]+0.2div. Set from 5mV/div to 200mV/div + 2mV; setting value from 200mV/div to 20V/div + 50mV? Under the same setting and condition, take the averege value for? Voltage difference between any two point of the waveform(? V):±(3% × Reading + 0.05div).±5 divisions from screen center. Trigger level average(typical)accuracy aims to the signal up and dowm times?
±(0.3div×V/div)(±4 divisions from screen center). ±(6% set value +40mV). Pre/Delay Trigger, pre-trigger depth adjustable.
Set the level to 50% (typical). Operate when Input singnal frequency? Rise, fall, rise and fall. Voltage value and time value of the waveform point. Allow cursor appear when auto measure.
Vpp, Amplitude, Vmax, Vmin, Vtop, Vbase, Vmed, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay A? +, -, ×, ÷, invert. 7inch TFT LCD, 800×480 pixels RGB. Adjustable light for waveform and grid. 1000 screen, Can be temporarily stored or stored to a USB flash drive.
One key copy screen function. USB-OTG:for digital storage and communicate with a PC. EU / UK / US (Optional).
220V (EU/UK plug), 110V (US plug), 50/60Hz. Working altitude 2,000M; storage altitude15,000M.
305 145 115mm / 12.0 5.7 4.5in. If you need us send the item to other address, please tell us. Please contact me before you return it. If item defective after 3 months, you can still send it back to us. We will send you a new one after receiving the defective item.We will get back to you in 12 working hours.